Single Phase Pad Mounted Transformer

Single Phase Pad Mounted Transformer Manufacturer

Attractek Transformer is a reputable manufacturer specializing in Single Phase Pad Mounted Transformers, widely trusted by utility companies across North America.

Our products are endorsed by UL and backed by test reports from globally recognized organizations like IEEE and CSA. With a wide range of advantages, Attractek Transformer stands out in the market:

  • Rich experience in providing utilities transformers
    solution across North America
  • Lightning delivery, providing transformers within 6-10 weeks.
  • Comprehensive aftermarket installation support in Texas and Houston.
  • Full range of UL and CSA listed transformers.
  • Single phase pad mounted transformers ranging from 10 kVA to 500 kVA.
12kV 225 kVA DOE Compliant Single Phase Pad Mounted Transformer
12.47kV 25 kVA IEEE Std Single Phase Pad Mounted Transformer
27.6kV 100kVA CSA standard Single Phase Pad Mounted Transformer
12.47kV 25 kVA Single Phase Pad Mounted Transformer

What are single phase pad mounted transformer?

Single phase pad mounted transformers are electrical devices used to step down high-voltage electricity from the power distribution network to a lower voltage that can be safely used in homes, small businesses, or other facilities.

Single-phase pad-mounted transformers typically step down medium voltage from the distribution grid (often in the range of 2.4 kV to 35 kV) to a lower voltage suitable for consumer use, such as 120/240 volts.

These transformers are mounted on the ground, typically within a locked, weatherproof metal enclosure, and are commonly installed in residential or light commercial areas.

 

Standard of single-phase pad-mounted transformer

Attractek single phase pad mounted transformers are produced comply with international standards such as ANSI/IEEE C57.12, IEC60076, IEC 61378, NEMA TR 1, CSA C227, etc.

With extensive international project experience transformer, Attractek single phase pad mounted transformers are not only comply with but also exceed the efficiency value requirements set by DOE and CSA.

DOE Efficiency requirement of Attractek single phase pad mounted transformers:

kVAEfficiency(%)
1098.7
1598.82
2598.95
37.599.05
5099.11
7599.19
10099.25
16799.33
25099.39

 

Attractek Transformer’s reliable and high-performance single phase pad mounted transformers are widely praised among our clients all over the world.

 

Specification of Single Phase Pad Mounted Transformer

Rated

Power

(KVA)

High

Voltage

(V)

LoW

Voltage

(V)

Dimension(mm)Loss(W)Reference

Weight

(KG)

WDHNo-load Loss (W)On-load Loss (W)
1534500/

19920

13800/

7967

13200/

7620

12470/

7200

Or others

120-240

240-480

347

600

61074084050195294
2561074084080290362
37.5610760840105360476
50610810840135500553
75610860840190650672
100740940910210850742
16776011909103501410952

Single Phase Pad Mounted Transformer Parts

Transformer Tank 

Typically made of steel and painted for corrosion resistance.
The tank is the outer casing that houses all internal components of the transformer. It is filled with insulating oil or uses dry-type insulation to dissipate heat and prevent electrical arcing.

Transformer Oil 

Insulating oil, such as mineral oil or biodegradable oil, is used in oil-filled transformers to insulate and cool the transformer. In dry-type transformers, the insulation is typically air or resin-based.

Bushings

Bushings are electrical insulators that allow the input (primary) and output (secondary) power connections to pass through the transformer tank. They are mounted on the top or sides of the transformer and are used to connect the transformer to the external power lines and load.

Primary and Secondary Windings

Primary Winding: This is the high-voltage winding connected to the incoming power supply (usually from the distribution line).
Secondary Winding: This is the low-voltage winding that delivers the reduced voltage to the load (i.e., homes, businesses, or equipment).
Both windings are typically made from copper or aluminum wire, wound around a core.

Core

The core is made of laminated silicon steel sheets to reduce eddy current losses and improve efficiency.
The core provides the magnetic path for the transformer, allowing electrical energy to be transferred from the primary winding to the secondary winding through electromagnetic induction.

Tap Changer (Optional)

Some transformers include a tap changer for adjusting the voltage levels. This component allows slight adjustments to the transformer’s voltage ratio, ensuring consistent voltage output regardless of slight fluctuations in input voltage or load.

Pressure Relief Valve

This safety feature releases pressure from the tank if the transformer experiences excessive internal pressure due to faults or overheating. It helps to prevent damage to the transformer tank.

Grounding Connection

Ensures safety by providing a direct electrical path to the ground in case of faults, which helps prevent electrical shock hazards.

Disconnect Switches

Some pad-mounted transformers are equipped with disconnect switches that allow the transformer to be isolated from the electrical grid during maintenance or repairs. This feature ensures safety by ensuring no live electrical connections are present during servicing.

Load Tap Changer (LTC) or Fuse (Optional)

Load Tap Changer: In some cases, a transformer may include an automatic or manual load tap changer (LTC) to adjust the voltage when load conditions change.
Fuse: A fuse or circuit breaker may also be included to protect the transformer and the connected equipment from overcurrent conditions.

Oil Level Indicator

This device indicates the level of insulating oil in the transformer tank, which helps monitor the condition and performance of the transformer. If the oil level drops too low, it may signal a leak or fault.

Overload Protection and Pressure Monitoring Devices

These safety devices monitor transformer conditions and help protect the transformer from overload, short circuits, or other hazardous conditions.

Feature of Single Phase Pad Mounted Transformer

 

  • Enclosure:The metal enclosure prevents accidental contact with live components and provides tamper-proofing. It is often padlocked for security.
  • Cooling:Most pad-mounted transformers use oil-filled cooling systems to dissipate heat generated during operation.
  • Bushings and Terminals:High-voltage bushings (where cables connect) and low-voltage terminals are provided inside the transformer for connections to both the power grid and consumer loads.

 

How Many kVA is a Single-Phase Pad Mounted Transformer?

Single phase pad mounted transformers typically range from 10 kVA to 250 kVA. In some cases, they can be rated up to 500 kVA for specific applications. The size selected depends on the anticipated electrical load and the specific requirements of the area they serve, such as residential neighborhoods or light commercial establishments.

 

Single Phase Pad mounted transformers are crucial for efficient electrical distribution. They step down high voltage to safer levels for residential and commercial use. Understanding their standards, kVA ratings, and applications is essential for selecting the right transformer for your needs.  At Attractek, we are committed to providing high-quality pole mounted transformers that meet your specific requirements.